Home >  Our Products > Step Voltage Regulator >  Automatic voltage regulator
Automatic voltage regulator
Single phase Automatic voltage regulator regulate each phase sperately,automatic voltage regulator monitor and control MODBUS,DNP3 communicate protocol could connector step voltage regulator to smart grid,HT voltage regulator is best and ecomnoic solution for those long distance transmission and distribution line voltage drop problem


inquiry
  • Description
  • Technical Specification
  • Comments

  • Farady step voltage regulator are designed for reliable operation and ease of maintenance and are supplied with a full array of standard features for routine applications.
    HT voltage regulator optional accessories are available to ac-accommodate special application it is also suitable for the energy saving projects for railway and urban grid. Farady transformer series step voltage regulator are available with a full complement of standard features for routine applications, as well as a full line of optional accessories for unique applications. In addition, the step voltage regulator offers desirable features that enhance operation and service.
    The step voltage regulator is basically a transformer that has its high-voltage winding (shunt) and low-voltage winding (series) connected to either aid or oppose their respective voltages. Subsequently, the output voltage of step voltage regulator could be the sum or difference between the winding voltages. For example, if the step voltage regulator has a turns ratio of 10:1 with 1000 V applied in the primary, then, the secondary voltage will be 100 V. Adding or subtracting by using the connection mentioned above - the output voltage of step voltage regulator would be 1100 V or 900 V, respectively. Thus, the step voltage regulator becomes an step voltage regulator with the capability to boost (raise/step-up) or buck (lower/step-down) the system voltage by 10%.


  • Overall size and weight


    Voltage
    (kV)


    Load Current (Amperes)

    kVA

    A(inch)

    B(inch)

    C(inch)

    D(inch)

    E(inch)

    Oil(L)

    Untanking WGT(LBS)

    WGT(LBS)

    7.62
    95kV
    BIL


    50

    38

    75

    68

    24

    38

    20

    220

    800

    1450

    100

    76

    75

    68

    25

    38

    20

    225

    820

    1650

    150

    114

    80

    75

    32

    45

    22

    250

    850

    1750

    219

    167

    82

    78

    36

    49

    22

    305

    980

    1890

    328

    250

    86

    80

    40

    61

    27

    511

    1580

    3250

    438

    333

    96

    90

    42

    63

    29

    731

    1988

    3887

    546

    416

    106

    100

    44

    67

    29

    855

    2222

    4730

    13.8
    95kV
    BIL


    50

    69

    80

    72

    28

    35

    20

    220

    860

    1450

    100

    138

    80

    72

    28

    47

    22

    275

    950

    1800

    150

    207

    82

    76

    40

    52

    25

    360

    1450

    2665

    200

    276

    95

    87

    40

    65

    28

    680

    2200

    4320

    300

    414

    105

    98

    43

    72

    33

    1100

    2350

    5700

    400

    552

    110

    105

    47

    72

    38

    1500

    2900

    7500




    Voltage (kV)

    Load Currer (Amperes)

    kVA

    A(inch)

    B(inch)

    C(inch)

    D(inch)

    E(inch)

    Oil(L)

    Untanking WGT(LBS)

    WGT(LBS)

    14.4
    150kV
    BIL


    50

    72

    75

    68

    27

    49

    22

    265

    860

    1680

    100

    144

    82

    74

    44

    45

    24

    350

    1280

    2250

    200

    288

    95

    87

    45

    57

    28

    555

    2000

    4000

    300

    432

    98

    91

    46

    67

    30

    800

    2650

    5000

    400

    576

    110

    100

    51

    71

    33

    1150

    3165

    6400

    19.92
    200kV
    BIL


    50

    100

    85

    76

    37

    50

    25

    400

    1000

    2100

    100

    200

    88

    80

    40

    56

    28

    580

    1800

    3300

    167

    333

    92

    86

    43

    58

    29

    680

    2200

    4120

    200

    400

    95

    88

    42

    67

    30

    800

    2700

    5000

    335

    667

    106

    95

    53

    73

    35

    1300

    3500

    6800




    control circuit diagram



Contact Us

+86-577-61722510

Our friendly customer service people are here to help you from 8.30am to 5pm Unique

Fax:+(86)-577-61777257

E-mail:info@farady.cn

Add:Su\\\'ao,Liushi,Yueqing,Zhejiang,P.R.China

Fast Register

  • By Registing you can download PDF on the website. take part in our monthly events receive emails from us!

Newsletter

  • Send me useful tips, industry articles and new product announcements (every month or so).

Top